韩国 日本 亚洲 国产 不卡_一级做a爱片久久毛片美图片_午夜中文福利无码在线 精品国产_3p国产对白刺激在线观看视频_肉动漫无遮挡在线观看免费_亚洲av色噜噜男人的天堂_好色先生tv污下载_国产私拍福利精品视频推出_91精品aⅴ无码中文字字幕蜜桃_大地资源免费更新

當(dāng)前位置:網(wǎng)站首頁 > 新聞中心 > 行業(yè)資訊
  • 冷庫安裝配電箱有哪些要求?
  • 本站編輯:杭州克冷制冷設(shè)備有限公司發(fā)布日期:2018-08-30 23:01 瀏覽次數(shù):

???é2???·?o?
冷庫安裝的過程中,冷庫配電箱的使用是一個非常重要的內(nèi)容。冷庫安裝之后,冷庫配電箱外面的配線必須要使用正確的方法來進行保護,比如說鋼管軟管這一些配線,我們盡量放在不容易受損的地方,否則就可能會導(dǎo)致冷庫配電箱的配線受到不必要的損害。同時,配電箱機床之間的電源線盡量放置在橋架中間,橋架也需要使用底座來起到支撐的作用,建議在使用橋架的時候,千萬不可以和地面直接接觸。
 
In the process of cold storage installation, the use of cold storage distribution box is a very important content. After the cold storage is installed, the distribution cables outside the cold storage distribution box must be protected by the correct method. For example, the distribution cables such as steel tube hose should be placed in the place where it is not easy to be damaged. Otherwise, it may cause unnecessary damage to the distribution cables of the cold storage distribution box. At the same time, the power line between the machine tools of distribution box is placed in the middle of the bridge as far as possible, and the bridge also needs to use the base to play a supporting role.
 
冷庫配電箱外面的配管也需要做到統(tǒng)一,這也是冷庫安裝后的一個重要內(nèi)容。如果存在不統(tǒng)一的現(xiàn)象,那么在后期的使用中,經(jīng)常性都會出現(xiàn)故障問題,浪費我們不必要的維修費用。
 
The distribution pipes outside the distribution box of the cold storage also need to be unified, which is also an important content after the installation of the cold storage. If there is a phenomenon of non-uniformity, then in the later use, frequent problems will occur, waste our unnecessary maintenance costs.
 
冷庫安裝時,對于配電箱包裝機或者是其他加熱設(shè)備的連接都需要重視起來,布線的時候,需要遠離靠近加熱的地方,接線盡量放置在連接箱里面,加熱器的連接線盡量使用玻璃或者是陶管電線,為了安全不可以使用可燃性電線。
 
Cold storage installation, for distribution box packaging machine or other heating equipment need to pay attention to the connection, wiring, need to stay away from the heating place, wiring as far as possible in the connection box, heater wiring as far as possible to use glass or pottery wire, in order to be safe not to use combustible electricity Line.
 
冷庫配電箱外面所有的電線在鏈接的時候都需要放在連接箱內(nèi),這也是冷庫安裝過程中的重要內(nèi)容,此外,連接線的中間不可以有接頭。
 
All the wires outside the cold storage distribution box need to be placed in the connection box when they are connected, which is also an important part of the cold storage installation process. In addition, there must be no connectors in the middle of the connection line.
 
冷庫配電箱所有的連接箱,電線入口的保護等級,全部都需要在IP55以上的標(biāo)準(zhǔn)。
 
All connection boxes of cold storage distribution boxes and protection levels of wire entrances all require standards above IP55.
 
中繼合端子臺盡量使用兩根電線進行鏈接,如果需要鏈接三根以上的電線,盡量設(shè)置其他的端子臺,否則也會影響到配電箱的正常使用。
 
If more than three wires need to be linked, try to set up other terminals, otherwise it will affect the normal use of distribution boxes.
 
感應(yīng)器在布線的時候如果放置在容易損害的地方,盡量使用軟管來起到保護的作用,軟管的使用,盡量直接安放在感應(yīng)器的根部,這一個內(nèi)容也是冷庫安裝時需要重視的。
 
If the sensor is placed in a vulnerable place when wiring, try to use hose to play a protective role, the use of hose, as far as possible directly placed at the root of the sensor, this content is also cold storage installation need to pay attention to.
 
同時,冷庫安裝之后,對于配電箱的正常使用,需要經(jīng)常性進行檢查,一旦出現(xiàn)隱患,必須要在第一時間進行處理,否則對于正常的使用會造成影響,甚至可能會造成經(jīng)濟損失。
 
At the same time, the cold storage installation, for the normal use of distribution boxes, need to be checked regularly, once there are hidden dangers, must be dealt with at the first time, otherwise for the normal use will affect, and may even cause economic losses.

  • 在線客服
  • 在線留言
  • 二維碼
  • 在線咨詢